Alerts & Learnings Catastrophic failure of mud centrifuge While processing drilling fluids, a mud centrifuge (Fig. 1) experienced a catastrophic failure resulting in the ejection of the pillow block bearing assembly. The 65 lb. assembly travelled approximately 190 ft before striking the steps of a living quarter trailer (Fig. 2). The gearbox, back drive electric motor, coupler and associated components were also dislodged from the frame but remained within the confines of the centrifuge platform. To view the original IADC Safety Alert, click on the 'Download Alert' button above. Download Alert Rate this Alert Your Rating Average Rating Share: Share on Linkedin Share on Facebook Share on Twitter Share with Email