Alerts & Learnings Catastrophic failure of pipework clamp connector (from HSE) The primary cause of failure of the clamp was due to hydrogen cracking. Evidence from this clamp and others checked later indicates that high hardness, with values in excess of 48-50HRC (Rockwell hardness value), being the underlying cause. High hardness increases the material's susceptibility to cracking in general from reduced ductility. Investigations revealed that prior to 2010 the clamps, which require quench and temper heat treatment, were not subject to 100% hardness testing. Hence the quality controls were not sufficient to detect components that had received improper heat treatment and lacked ductility. Clamp connector segments are produced by a forging process in a number of foundries in the UK and are manufactured from AISI 4140 alloy steel with a recommended Rockwell hardness value of 22HRC. To date all defective clamps found were produced by one manufacturer (George Dykes) and supplied to Vector Technology Group (Techlok) up until 2010. These were limited to 2" diameter clamps and below. It has subsequently been established that the similar 'G' clamp supplied by Destec Engineering, was also manufactured by George Dykes. A Destec 'G' clamp is also known to have failed in service in 2014. The confirmed numbers of failed clamps is low and they appear to be random and not batch related, therefore it is not possible to identify them through heat numbers or heat treatment records. Rate this Alert Your Rating Average Rating Share: Share on Linkedin Share on Facebook Share on Twitter Share with Email