Alerts & Learnings Damage to Wireline Unit During Supply Boat Operations Whilst backloading a container to a supply vessel using the platform crane, it touched down to the supply vessel deck, a secured door unexpectedly opened on the container and then the stern deck of the supply vessel immediately dropped. When the vessel came back up, the door impacted an adjacent pipe carrier basket on the vessel and damaged the hinges on the door. The unit was recovered back to the platform so it could be examined and made safe. Findings:The unit had passed a thorough inspection against EN 12079 1999 which requires the design standard to be headed on the container nameplate and double doors to have at least one locking device on each door, that locks directly to the top and to the bottom frame. Neither requirement was met.The door locking device was in the closed position prior to landing, with a single tie wire used as secondary retention. However, the locking device moved into the open position under the force of the landing. Weather conditions and sea state were within the acceptable limits.The landing area on the supply vessel was too small to land the unit with the open door. With the information the crane operator had at the time; they made the split decision to recover the container to the platform as they deemed it the safest option to take. Download Alert Rate this Alert Your Rating Average Rating Share: Share on Linkedin Share on Facebook Share on Twitter Share with Email
Alert 28 Jul 2025 Potential Dropped Objects (PDOs) returned with units In the offshore environment Potential Dropped Objects (PDO’s) are a major safety risk as the transportation of units is normally completed using cranes and lifting items great heights. This poses the risk of items falling and striking personnel in the vicinity. Over the years, many PDO’s have been d… View Alert
Alert 10 Jun 2025 Dropped Object Due to Corroded Deluge Flange After landing a lower completion assembly on the drill floor and while retracting the deck crane whip line and twin hook stinger back through the v-door, the twin hook stinger swung to starboard causing one of the hooks to strike a blanking flange on the drill floor deluge line. The 4.95kg blanking … View Alert
Alert 10 Jun 2025 Rust Particle Enters Eye During Spool Removal A Mechanical Tech was tasked with the removal of a spool. Due to the location of the spool, the technician had to work in a restricted space, lying on their back to access the flange bolts. During removal, the IP felt what they believed to be rust, hit their face. Following this, the IP re-positione… View Alert