Alerts & Learnings Diver lifted off seabed A diver was lifted off the seabed when their umbilical was caught by a diving bell clump weight adjustment prior to bell recovery. When moving from the bell to the worksite, a bight of the Starboard Diver 2’s umbilical fouled on the port bell clump weight. When the port bell was raised to a short mark (approximately 10m from deployed position) by the Diving Supervisor, Starboard Diver 2 was lifted off the seabed to a height of approximately 4-5m due to the caught umbilical. Upon recognition that the diver had been lifted off the seabed, the Diving Supervisor called an ALL STOP and the port bell clump weight was lowered until Starboard Diver 2’s umbilical was cleared. The diver returned to the bell, where he and his equipment was assessed. At no point did the diver lose any of his services. Diver 2 was cleared to return to work using Diver 3’s equipment. (The bell in use was configured to having 3 working divers out of the bell in addition to the bellman). To view this safety alert published by IMCA in full, click the 'Download Alert' button above. Download Alert Rate this Alert Your Rating Average Rating Share: Share on Linkedin Share on Facebook Share on Twitter Share with Email
Alert 28 Jul 2025 Potential Dropped Objects (PDOs) returned with units In the offshore environment Potential Dropped Objects (PDO’s) are a major safety risk as the transportation of units is normally completed using cranes and lifting items great heights. This poses the risk of items falling and striking personnel in the vicinity. Over the years, many PDO’s have been d… View Alert
Alert 10 Jun 2025 Dropped Object Due to Corroded Deluge Flange After landing a lower completion assembly on the drill floor and while retracting the deck crane whip line and twin hook stinger back through the v-door, the twin hook stinger swung to starboard causing one of the hooks to strike a blanking flange on the drill floor deluge line. The 4.95kg blanking … View Alert
Alert 10 Jun 2025 Rust Particle Enters Eye During Spool Removal A Mechanical Tech was tasked with the removal of a spool. Due to the location of the spool, the technician had to work in a restricted space, lying on their back to access the flange bolts. During removal, the IP felt what they believed to be rust, hit their face. Following this, the IP re-positione… View Alert