IADC - Fall from height whilst descending derrick ladder and harnessed

Injured person (IP) had just completed untying a double stand of drill pipe that was lashed to the derrick. IP

connected full body harness to the cable sleeve of the fall-arrest system and started to descend the derrick ladder

when his foot slipped on a rung, causing him to fall 6-7 ft. (approx. 2 m) to the intermediary platform below.

CONTRIBUTING FACTORS:

The installed fall-arrest system failed to stop IP’s fall over a 6-7ft. distance.The fall-arrest manufacturer’s technical specifications indicate that it may not stop a fall immediately and thata minimum clearance of 7ft. (2m) is required between the user’s feet and the surface below for the system to stop the fall of an average person.