Alerts & Learnings Serious foot injury on walk-to work gangway The gangway of a walk-to-work vessel was connected to a satellite platform Two operators crossed the gangway first, as per normal procedure. The third person (IP) was in the process of crossing the gangway when a red light was signaled, indicating the request to return to the vessel. The red light was not noticed at first by the IP, as he was focusing on his footsteps. When the IP became aware of the red light, he turned around to return to the vessel. At this point his left foot got stuck against the junction between the static and dynamic sections of the gangway, resulting in severe injury to the left foot. IP received first aid onboard the vessel and a call was made for immediate medevac - the IP was transferred to the hospital by helicopter Actual Consequence:• Serious injury resulting in permanent disability Findings: • This incident occurred when the IP entered the dynamic section of the gangway. The IP's turning motion and foot placement, while attempting to return to the vessel, combined with compensating movements within the dynamic section of the gangway towards the static section, likely resulted in the IP’s boot becoming trapped between the air gap and the grating of the dynamic part. This entrapment occurred as the dynamic section was adjusting to sea conditions by moving towards the static part. • The gangway was inspected after the incident and was found to be functioning as intended. • No technical defects have been identified. The gap between the static and the dynamic sections of the gangway was measured to 20mm. • The vessels dynamic positioning system and associated gangway system were both operating within allowable parameters. Download Alert Rate this Alert Your Rating Average Rating Share: Share on Linkedin Share on Facebook Share on Twitter Share with Email